  • LoadRunner中遇到的问题及解决方法(累积)

    2008-12-03 12:51:05

    问题1:LoadRunner录制脚本时,不能自动打开浏览器。
    解决措施:启动IE->Internet选项->高级,勾掉“启用第三方浏览器扩展(需要重启动)”->重新启动运行VuGen录制脚本。

    问题2:安装LoadRunner中文语言包不成功(停留在99%或安装错误)
    解决措施:

    1、LoadRunner中文语言包的放置路径中不能有中文!
    2、LoadRunner中文语言包放置的目录不能太深,否则会安装不成功。(建议将汉化包拷贝到磁盘的根目录下进行安装!例如 D:\)

  • LoadRunner 链接QC问题及解决方法

    2008-11-18 13:36:52

    使用Loadrunner->工具->qc连接,输入http://qc服务器IP:端口/qcbin后

    出现错误消息

    (1)“Failed to create list of projects on current Quality Center server.”
    (2)“Failed to Get Domain List.
    (3)“Server has been disconnected while performing GetDomainList action”

    诊断:This error may occur with previous version of QuickTest Professional, WinRunner, or LoadRunner, which do not support the new authentication procedure that TestDirector for Quality Center 9.0 uses. This can also happen when using the QC OTA API to create any utilities to connect to QC projects.


    解决方法:Define BACKWARD_SUPPORT_ALL_DOMAINS_PROJECTS as "Y" in the Site Administrator
    This parameter enables the use of DomainList and ProjectsList properties for the purposes of backward compatiblity. If this parameter is set to "Y," the DomainList and ProjectsList properties are supported.

     

    操作步骤:

    1. Launch the Site Administrator.
    2. Select the Site Configuration tab.
    3. Set the value for BACKWARD_SUPPORT_ALL_DOMAINS_PROJECTS to Y.

    附加说明:

    If the parameter does not exist, you will need to add it.


     