PMP ,专注于WEB功能测试、性能测试、安全测试的研究,从事全面质量管理工作。曾任多家公司测试经理、测试主管。在电子政务、银行、电商、跨境电商、直播电商领域工作多年,曾获得某龙头集团公司公测一等奖,曾任职某头部直播电商公司测试团队负责人,具有业务敏感性,擅长从0到1搭建测试团队,具有海外工作经历,以及质量管理体系搭建。邮箱:89233502@qq.com

IBM APPSCAN8.002 ifix001 internal error 1412-1 BUG

上一篇 / 下一篇  2011-07-20 12:04:52 / 个人分类:我爱找茬

AppScan 7.8 fails to start on some localized operating systems

 Technote (troubleshooting)
 
Problem(Abstract)
This technote identifies an AppScan Severe Error Internal error 1412-1 that can occur in localized versions of IBM Rational AppScan Standard Edition, and provides a workaround.
 
Symptom
On localized Czech version of Microsoft Windows, after installing or upgrading from version 7.7, AppScan 7.8 fails to start with the following error:
Note: This error might occur on other localized versions of Microsoft Windows.

    AppScan Severe Error
    Internal error 1412-1. AppScan need to terminate.

 
Resolving the problem
This has been identified as a defect in AppScan 7.8, referenced as APAR PK80452.
The following workaround is available:
  1. Create a temporary directory with only English characters, for example: c:\temp
  2. Create a system variable with the name: APPSCAN_TEMP and the value:c:\temp (or whatever directory you have just created in the first step).

This will allow AppScan to start normally.

7.7 和7.8 版本的同学出现此问题后可尝试上述方法

BUG1按照上面的方法 添加系统变量后  在8.002 ifix 001版中 导入扫描文件时 又出现这个问题   看来是新版的 BUG 

BUG2从其他机器拷贝过来 同一版本的扫描文件 会出现错误  提示

“由于系统错误,无法继续当前的配置  请配置新的扫描”


APPSCAN 8.0版本 还是有很多 BUG 的  , 测试普通网站还行   扫描大的门户网站   不停的出问题   IBM 的工程师们要加油了 