LoadRunner 链接QC问题及解决方法

上一篇 / 下一篇  2008-11-18 13:36:52 / 个人分类:loadrunner相关

使用Loadrunner->工具->qc连接,输入http://qc服务器IP:端口/qcbin后

出现错误消息

(1)“Failed to create list of projects on current Quality Centerserver.”
(2)“Failed to Get Domain List.
(3)“Server has been disconnected while performing GetDomainList action”

诊断:This error may occur with previous version of QuickTest Professional,WinRunner, orLoadRunner, which do not support the new authentication procedure that TestDirector for Quality Center 9.0 uses. This can also happen when using the QC OTA API to create any utilities to connect to QC projects.


解决方法:Define BACKWARD_SUPPORT_ALL_DOMAINS_PROJECTS as "Y" in the Site Administrator
This parameter enables the use of DomainList and ProjectsList properties for the purposes of backward compatiblity. If this parameter is set to "Y," the DomainList and ProjectsList properties are supported.

 

操作步骤:

1. Launch the Site Administrator.
2. Select the Site Configuration tab.
3. Set the value for BACKWARD_SUPPORT_ALL_DOMAINS_PROJECTS to Y.

附加说明:

If the parameter does not exist, you will need to add it.


 


TAG: loadrunner相关

 

评分:0

我来说两句

日历

« 2024-03-23  
     12
3456789
10111213141516
17181920212223
24252627282930
31      

数据统计

  • 访问量: 48808
  • 日志数: 19
  • 建立时间: 2008-11-13
  • 更新时间: 2008-12-16

RSS订阅

Open Toolbar