在测试中寻找乐趣,在乐趣中寻求进步

LoadRunner测试Oracle10g常见问题(5)

上一篇 / 下一篇  2007-12-03 12:15:43 / 个人分类:

11月29日(星期四)

性能监视相关。

问题9:压力机资源监视
Monitor name :Windows Resources. Cannot connect to machine lr071129.Reason: 找不到网络路径。


解决:
在弹出的Add Machine窗口,name项输入IP地址,正确选择Platform。

问题10:UNIX资源监视问题
Monitor name :UNIX Resources. Cannot initialize the monitoring on 10.152.**.**. Error while creating the RPC client. Ensure that the machine can be connected and that it runs the rstat daemon (use rpcinfo utility for this verification). Detailed error: RPC: Failed to create RPC client.
RPC-TCP: Failed to establish RPC server address.
RPC-TCP: RPC Server <100001, 3, 17> is not registered on host '10.152.11.26'. (entry point: CFactory::Initialize). [MsgId: MMSG-47190]


解决:
[root@oratest ~]# cd /etc/rc.d/init.d
[root@oratest init.d]# ll | grep rstatd*
-rwxr-xr-x 1 root root 1009 May 4 2005 rstatd
[root@oratest init.d]# ./rstatd start
Starting rstat services: [ OK ]
[root@oratest init.d]#