Remove Simplified Scripting from scripts in IBM Rational Functional Tester

上一篇 / 下一篇  2010-07-07 13:07:19 / 个人分类:RFT

http://www-01.ibm.com/support/docview.wss?uid=swg21405134

Question

How do I remove the Simplified Scripting component from existing scripts in IBM Rational Functional Tester?

Cause

Simplified Scriptingmode is enabled by default in IBM Rational Functional Tester 8.1 and above. You may want to disable this functionality for reasons such as


Simplified Scripting mode can be toggled on and off at the setting shown below.
Window > Preferences > Functional Test > Simplified Scripting > Enable Simplified Scripting

However,theEnable Simplified Scriptingpreference only affects newly created scripts. Existing scripts that were created with Simplified Scripting mode enabled will still have the Simplified Scripting view and functionality, as denoted by the blue script. icon and also by the Script/Java tabs in the script. editor.


This technote describes how to convert existing scripts created using Simplified Scripting mode into standard Rational Functional Tester Java scripts.

Answer

Follow the steps below to permanently remove the Simplified Scripting component from existing scripts in a Rational Functional Tester project.

This is a one-way process. It is not possible to convert a standard Java Scripting script. into a Simplified Scripting mode script.

  1. Right-click your project and chooseProperties.
  2. Make note of the Location, then click OK to close the Properties window.
  3. Right-click your project and choose Disconnect Project.
  4. In Windows Explorer, navigate to the project folder (the Location you made note of in step 2). Delete*.rftss.
  5. In Functional Tester, clickFile > Connect to a Functional Test Project.
  6. Click Browse and navigate to the project folder (the Location you made note of in step 2. ClickOKand then clickFinish.
  7. Verify that your scripts no longer have the Simplified Scripting view and functionality, as denoted by the yellow script. icon, and by the lack of Script/Java tabs at the bottom of the script. editor.

For more information in the Simplified Scripting feature, seeWorking with Simplified Scriptingin the IBM Rational Functional Tester documentation.

BACKING UP FILES:
Always make new database back-ups of your schema repository and users databases prior to making schema changes and performing database upgrades. Failure to create back-up copies can limit your ability to recover from a an upgrade failure, design change issues or other unforeseen failures.



TAG:

 

评分:0

我来说两句

日历

« 2024-05-13  
   1234
567891011
12131415161718
19202122232425
262728293031 

数据统计

  • 访问量: 18187
  • 日志数: 20
  • 建立时间: 2010-06-09
  • 更新时间: 2010-11-23

RSS订阅

Open Toolbar